Oncotarget

Meta-Analysis:

Diagnostic accuracy of BRCA1–associated protein 1 in malignant mesothelioma: a meta-analysis

Li-Ming Wang, Zhen-Wang Shi, Ji-Ling Wang, Zhi Lv, Fang-Bin Du, Qing-Bin Yang and Yong Wang _

PDF  |  HTML  |  How to cite

Oncotarget. 2017; 8:68863-68872. https://doi.org/10.18632/oncotarget.20317

Metrics: PDF 2107 views  |   HTML 2118 views  |   ?  


Abstract

Li-Ming Wang1, Zhen-Wang Shi1, Ji-Ling Wang2, Zhi Lv2, Fang-Bin Du2, Qing-Bin Yang2 and Yong Wang2

1Department of Gastroenterology, Second People’s Hospital of Hefei, Anhui, China

2Department of Respiratory Medicine, Second People’s Hospital of Hefei, Anhui, China

Correspondence to:

Yong Wang, email: [email protected]

Qing-Bin Yang, email: [email protected]

Keywords: diagnostic accuracy, diagnostic accuracy, malignant mesothelioma, malignant mesothelioma, BAP1

Received: April 14, 2017     Accepted: August 06, 2017     Published: August 17, 2017

ABSTRACT

Background: Conventional measurements are not always helpful in the diagnosis of malignant mesothelioma (MM). Increasing studies indicate that loss of BRCA1–associated protein 1 (BAP1) detected by immunohistochemistry (IHC) is a useful diagnostic marker for MM. In this meta-analysis, we investigated the diagnostic accuracy of BAP1 in MM.

Results: In total, 12 eligible studies with a total of 1824 patients were selected. Results indicated that loss of BAP1 sustained a pooled sensitivity of 0.56 (95% CI, 0.50–0.62), specificity of 1.00 (95% CI, 0.95–1.00), PLR of 548.82 (95% CI, 11.31–2.7 × 104), NLR of 0.44 (95% CI, 0.39–0.50), DOR of 1247.78 (95% CI, 25.08 –6.2 × 104) in discriminating MM from non-MM. The AUC of 0.72, reflecting the SROC, indicated moderate diagnostic accuracy. Subgroup analysis showed that BAP1 detection in histological specimens owned the higher diagnostic performance than cytological ones. In addition, BAP1 showed superior diagnostic accuracy in epithelioid MM than biphasic or sarcomatoid MM.

Materials and Methods: PubMed, Embase and the Cochrane Library and reference lists of related articles were searched, and studies that evaluated the utility of BAP1 in MM were included. Data from eligible studies were pooled to estimate sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR). Summary receiver operating curves (SROC) was applied to estimate overall diagnostic accuracy.

Conclusions: Current meta-analysis indicates that detection of BAP1 by IHC is a useful diagnostic marker for MM. Loss of BAP1 almost provides confirming diagnosis for MM, while positive staining for BAP1 is not enough to exclude non-MM.


Creative Commons License All site content, except where otherwise noted, is licensed under a Creative Commons Attribution 4.0 License.
PII: 20317