Oncotarget

Clinical Research Papers:

The application of IS6110-baced loop-mediated isothermal amplification (LAMP) in the early diagnosis of tuberculous meningitis

Wen-Wen Sun, Qin Sun, Li-Ping Yan and Qing Zhang _

PDF  |  HTML  |  How to cite

Oncotarget. 2017; 8:57537-57542. https://doi.org/10.18632/oncotarget.15734

Metrics: PDF 1521 views  |   HTML 2920 views  |   ?  


Abstract

Wen-Wen Sun1,*, Qin Sun1,*, Li-Ping Yan1 and Qing Zhang1

1 Clinic and Research Center of Tuberculosis, Shanghai Key Laboratory of Tuberculosis, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China

* Co-first author

Correspondence to:

Qing Zhang, email:

Keywords: tuberculous meningitis (TBM), diagnosis, loop-mediated isothermal amplification

Received: January 17, 2017 Accepted: February 08, 2017 Published: February 25, 2017

Abstract

Here, we evaluated the potential activity of rapid Mycobacterium tuberculosis detection with loop-mediated isothermal amplification (LAMP), for the early diagnosis of tuberculous meningitis (TBM). Patients with suspected TBM from January 2014 to December 2015 were reviewed retrospectively. The cerebrospinalfluid(CSF) was collected. Acid-fast bacillus (AFB) staining, MGIT 960 culture, real-time fluorescent quantitative polymerase chain reaction (RTFQ PCR) and LAMP were performed. A total of 200 patients were included in the study. Of which, 172 of them were diagnosed with TBM (86.00%). The sensitivities of AFB staining, MGIT 960 culture, LAMP and RTFQ PCR for TBM diagnosis were 2.91% (5/172), 12.79% (22/172), 43.02% (74/172), and 34.30% (59/172), respectively. The sensitivity of LAMP for TBM was significantly higher than those of AFB staining and MGIT960 culture (χ2 = 75.11, P < 0.001; χ2 = 43.88, P = 0.002). LAMP’s sensitivity was however comparable to RTFQ PCR assay (χ2 = 2.08, P = 0.130). The specificity, positive predictive value and negative predictive value of LAMP in the diagnosis of TBM were 92.86% (26/28), 97.37% (74/76) and 20.97 % (26/124), respectively. The overall consistency between LAMP and RTFQ PCR in the diagnosis of TBM was 88.5% (177/200), with Kappa value of 0.870. The consistency between LAMP and MGIT960 culture was 71% (142/200), with Kappa value of 0.730. Among all the methods, LAMP had high sensitivity, specificity and positive predictive value, showing high consistency with MGIT960 culture and RTFQ PCR.


Creative Commons License All site content, except where otherwise noted, is licensed under a Creative Commons Attribution 4.0 License.
PII: 15734